Сердечно-сосудистые заболевания и диагностика

Отправить рукопись arrow_forward arrow_forward ..

Fluoroscopy-Guided Axillary Vein Puncture, a Reliable Method to Prevent Acute Complications Associated With Pacemaker, Defibrillator, and Cardiac Resynchronization Therapy Leads Insertion

Abstract

E.M. Malitha S. Hettiarachchi, Camelia Arsene, Salah Fares, Adriss Faraj, Erik Saulitis, Salvatory Losito and Mukarram Siddiqui

Introduction: The subclavian venous approach is a widely used method for venous access in device implantation and is associated with pneumothorax as a short term complication and lead fracture as a long term complication. The axillary vein approach is an alternate method for venous access, and this study evaluates the successfulness and immediate complications of fluoroscopy-guided axillary vein puncture compared to other venous approach methods.

Methods: This is a retrospective observational study on all patients who underwent pacemaker, defibrillator implant or lead change over 23 months. The fluoroscopy-guided modified Seldinger technique was used for axillary vein puncture and if failed, venography was performed.

Results: Out of 261 device implants or lead changes, 210 patients underwent fluoroscopy-guided axillary vein puncture. The mean age of the patients was 65.43 ± 15.7 years; 96.1% were African American; 57.6% were males. In 194 (92.3%) patients left or right axillary vein approaches were successful by either fluoroscopy or venography guidance. When anatomical abnormalities were excluded the success rate for axillary vein puncture was 97% and for fluoroscopy-guided axillary vein puncture was 94.5 %. Multiple leads were placed without any resistance and none of the patients had pneumothorax, hemothorax or hematoma as immediate complications.

Conclusion: Based on this first study conducted in a relatively large consecutive United Sates patient population, we report that fluoroscopy-guided axillary vein puncture using the first rib as a landmark, is a safe and effective method for device implantation with single or multiple leads, without patients getting exposed to intravenous contrasts.